Quanticon™ Mouse ACAT2(Acetyl Coenzyme A Acetyltransferase 2) ELISA Kit


Quanticon™ Mouse ACAT2(Acetyl Coenzyme A Acetyltransferase 2) ELISA Kit
Quanticon™ Mouse ACAT2(Acetyl Coenzyme A Acetyltransferase 2) ELISA Kit
Principle of the Procedure
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ACAT2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ACAT2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ACAT2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ACAT2 in the samples is then determined by comparing the OD of the samples to the standard curve.
Product Name | Quanticon™ Mouse ACAT2(Acetyl Coenzyme A Acetyltransferase 2) ELISA Kit | ||
SKU | ABQK-ES96-ACAT2ms | ||
Applications | ELISA | ||
Type of Elisa | Traditional Elisa | ||
Mouse | Mouse | ||
Alternative Name | ACTL, Acetoacetyl Coenzyme A Thiolase, Acetyl-CoA transferase-like protein, Cytosolic acetoacetyl-CoA thiolase | ||
Standard | 10 ng/mL | ||
Sensitivity | 0.057 ng/mL | ||
Detection Range | 0.16-10 ng/mL | ||
Sample Type | Serum, Plasma, Tissue homogenate, Cell lysates, Urine, Saliva, Cerebrospinal fluid (CSF), Cell culture supernatant and Other biological samples | ||
Sample Volume | 100 ÎĽL | ||
Assay Type | Sandwich | ||
Assay Duration | 3.5 H | ||
Detection Wavelength | 450nm | ||
Storage | 2-8oC/-20 oC | ||
Kit Components details | |||
 Reagents | Quantity (48T) | Quantity (96T) | Storage Condition |
Pre-Coated Microplate | 6 strips x 8 wells | 12 strips x 8 wells |  4°C/-20°C |
Standard (Lyophilized) | 1 vial | 2 vials |  4°C/-20°C |
Biotinylated Antibody (100×) | 60 μL | 120 μL |  4°C/-20°C |
Streptavidin-HRP (100×) | 60 μL | 120 μL |  4°C/-20°C |
Standard/Sample Diluent Buffer | 10 mL | 20 mL |  4°C/-20°C |
Biotinylated Antibody Diluent | 6 mL | 12 mL |  4°C/-20°C |
HRP Diluent | 6 mL | 12 mL |  4°C/-20°C |
Wash Buffer (25×) | 10 mL | 20 mL |  4°C/-20°C |
TMB Substrate Solution | 6 mL | 10 mL | 4°C/-20°C (store in dark) |
Stop Reagent | 3 mL | 6 mL |  4°C/-20°C |
Plate Covers | 1 piece | 2 pieces | Â RT |